Gestational Diabetes Screen (ACOG Recommendations)

Create a Free Account to View Prices

Category:

Turnaround Time: Within 1 day
CPT Code:

82950

Test Type: 1 mL serum or plasma each tube Serum or plasma
Stability Time:

Temperature

Period

Room temperature

14 days

Refrigerated

14 days

Frozen

14 days

Freeze/thaw cycles

Stable x3

Reference Range:

65-139 mg/dL Critical Value <40 mg/dL or >500 mg/dL

Overview:

Screening test for gestational diabetes.

The American College of Obstetricians and Gynecologists (ACOG) recommends that all pregnant women be screened for gestational diabetes mellitus (GDM)—whether by patient history, clinical risk factors, or with a 50-gram, one-hour loading test at 24 to 28 weeks of gestation to determine blood glucose levels—and suggests relying on the result of the 100-gram, three-hour oral glucose tolerance test for diagnosis (often referred to as a "two-step" method).2

The American Diabetes Association (ADA)3 released standards that vary from the ACOG recommendations. The ADA recommends a simplified "one-step" approach to the screen and diagnosis of gestational diabetes mellitus with a 75-gram, two-hour glucose tolerance test. The LabCorp test according to the ADA recommendations is Gestational Glucose Tolerance Screening and Diagnostics Test (Two-hour, ADA Recommendations) [101000]. A glucose tolerance screen glucose threshold >139 mg/dL after a 50-gram load identifies approximately 80% of women with gestational diabetes mellitus, while the sensitivity is further increased to approximately 90% by a threshold >129 mg/dL. Perform a diagnostic 100-gram oral glucose tolerance test (102004) on a separate day on women who exceed the chosen threshold on 50-gram screening.

1. LabCorp internal studies.

2. American College of Obstetricians and Gynecologists. Committee on Practice Bulletins—Obstetrics. Practice Bulletin N° 137: Gestational diabetes mellitus. Obstet Gynecol. 2013 Aug; 122(2 Pt 1):406-416. PubMed 23969827

3. American Diabetes Association. Standards of Medical Care in Diabetes—2015: Summary of revisions. Diabetes Care. 2015 Jan; 38(Suppl 1):S4. PubMed 25537706

Collection Details:

Patient Preparation:

None; glucose challenge is administered without regard to time of day or time of last meal.

Collection Instructions:

The patient need not be fasting. The one-hour screen requires a 50-gram oral glucose load followed by a plasma glucose determination one hour later. (Refer to Additional Information below.) See the online Endocrine Appendix: Glucose Tolerance: Gestational Diabetes Mellitus for further information regarding glucose tolerance testing.

Gel-barrier tube or gray-top (sodium fluoride/potassium oxalate plasma) tube.

Note: A fasting blood sample is not required. Draw one hour specimen after a 50-gram glucose challenge. The patient should remain seated and not smoke throughout the test. Submit 1 mL serum or plasma for one-hour specimen. Separate serum or plasma from cells within 45 minutes of venipuncture. Gray-top tubes only, may be submitted without centrifugation. Label tube with patient's name and collection time interval (ie, one-hour).

Maintain specimen at room temperature.1