Gynecologic Pap Test (Image-guided), Liquid-based Preparation

Create a Free Account to View Prices

Category:

Turnaround Time: 2 - 5 days
CPT Code:

88175

Test Type: Entire vial

Overview:

Failure to obtain adequate ectocervical, endocervical, or vaginal cell population is suboptimal for evaluation. Excessive use of lubricating jelly on the vaginal speculum will interfere with cytologic examination and may lead to unsatisfactory Pap results.

Hutchinson ML, Cassin CM, Ball HG 3rd. The efficacy of an automated preparation device for cervical cytology. Am J Clin Pathol. 1991 Sep; 96(3):300-305. PubMed 1877527

Hutchinson ML, Isenstein LM, Goodman A, et al. Homogeneous sampling accounts for the increased diagnostic accuracy using the ThinPrep® processor. Am J Clin Pathol. 1994 Feb; 101(2):215-219. PubMed 8116578

Joseph MG, Cragg F, Wright VC, et al. Cytohistological correlates in a colposcopic clinic: A 1-year prospective study. Diagn Cytopathol. 1991; 7(5):477-481. PubMed 1954825

Wilbur DC, Cibas ES, Merritt S, James LP, Berger BM, Bonfiglio TA. ThinPrep® Processor: Clinical trials demonstrate an increased detection rate of abnormal cervical cytologic specimens. Am J Clin Pathol. 1994 Feb; 101(2):209-214. PubMed 8116577

Collection Details:

Patient Preparation:

Patient should avoid douches 48 to 72 hours prior to examination. Specimen should not be collected during or shortly after menstrual period. Excessive use of lubricating jelly will interfere with cytologic examination.

Collection Instructions:

ThinPrep® vial or SurePath™ vial.

ThinPrep® Vial − Broom or Brush/Spatula:

Broom-like collection technique: Obtain a sample from the cervix using a broom-like device by inserting the brush portion into the cervical os and rotate the brush five times. Rinse the collection device in the PreservCyt® solution by pushing the brush into the bottom of the vial 10 times, forcing the bristles to bend apart to release the cervical material. As a final step, twirl the brush between the thumb and forefinger vigorously to release additional cellular material. Discard the collection device. Tighten the cap on the ThinPrep® vial so that the torque line on the cap passes the torque line on the vial.

Brush/spatula technique: Insert the brush into the endocervical canal until only the bottommost fibers are exposed. Slowly rotate the brush 1/4 to 1/2 turn in one direction. Do not over-rotate the brush. Then, rotate the brush in the PreservCyt® solution 10 times while pushing against the wall of the ThinPrep® vial. Swirl the brush vigorously to release additional material. Discard the brush. Obtain an adequate sample from the ectocervix using a plastic spatula. Swirl vigorously in the ThinPrep® vial 10 times and discard the spatula. Tighten the cap on the ThinPrep® container so that the torque line on the cap passes the torque line on the vial.

SurePath™ Vial: When using the SurePath™ vial, the cervical broom must be used for specimen collection. Insert the broom into the cervical os and rotate five times. Place the broom head into the CytoRich™ preservative fluid in the SurePath™ collection vial. Tightly cap the vial.

Maintain specimen at room temperature. Specimens must be processed for testing within 21 days of collection.